3.1.2. CERTIFICATION:
The Cameras Offered by the Tenderer shall be UL Approved and conform to
ONVIF Standards (Open Network Video Interface Forum) and for the product safety the
camera shall comply with CE Regulations UL, CSA, EN, and IEC Standards.
3.1.3 CAMERA MOUNTING STRUCTURES:
All the Cameras shall be supplied along with aesthetically designed G.I.Mounting
structures as detailed below :-
1) shall have a total height of 2500 mm.
2) shall have suitable bottom plate welded to the GI pipe for grouting on the
ground.
3) The GI pipe and other brackets welded to it shall anodized to with stand the
hostile environmental conditions.
4) The top of the pipe shall be closed with plate to prevent dust/water getting into
the pipe.
5) The scope of work will also include installation of the mounting structures for all
the cameras at the locations pointed out by Trust including construction of concrete
pedestal for grouting/fixing the GI Structure.
3.1.4 8 PORT AND 16 PORT 10/100/1000 SWITCHER
QUANTITY REQUIRED:
a) 8 PORT SWITCHER: 6 Numbers
b) 16 PORT SWITCHER:4 Numbers
Tenderer shall supply, Install and Commission necessary 8 and 16 port switchers
complete with all accessories for viewing the video signals individually at Centralized
Video Surveillance system control room (CVSS) as per technical specification given
below
MAKE: D-LINK / DAX /CISCO only.
STANDARDS IEEE 802.3,802.3u,802.3x and 802.3ab
PORTS 8 Port(min) and 16 Port (min) RJ45 10/100/1000 +2 mini-GBIC
Ports
CABLING TYPE Category 5 Ethernet or Better
LED System 1 through 24